When your project demands measurement without compromise, turn to the MS AX motorized total station for guaranteed performance. Major civil engineering tasks often demand the highest possible accuracy and reliability, and the MS total station series will surpass your expectations. A solution for the ultra-precise measurement of dimensions and geometry, the MS series was designed to meet the needs of manufacturing, service, and maintenance. Set your expectations high when accuracy is paramount for projects that must monitor displacement and deformation.
{"sku":"SKU|MS_series","model":"Model|MS series","feature_bullet_1":"Feature 1|Angular accuracy option of either 0.5 inch or 1 inch","feature_bullet_2":"Feature 2|Reliable distance accuracy at 0.5 mm","feature_bullet_3":"Feature 3|Rapid and customizable 2D monitoring","feature_bullet_4":"Feature 4|Auto-collimation accuracy of 1 inch","feature_bullet_5":"Feature 5|Automated Matrix Detection and Target Acquisition","product_brochure_url":"Product Brochure PDF URL|https://www.topconpositioning.com/sites/default/files/product_files/ms_axii_series_broch_7010_2083_reve_sm.pdf","spec_notab_clustered_specs":"Specifications|
Accuracy*: MS1AXII: ; 1” (0.3mgon*)
Minimum Reading: MS05AX: ; 0.1 inch (0.02 mgon)
Minimum Reading: MS1AX: ; 0.5 inch( 0.1 mgon)
Non-Prism Mode: MS1AX: ; 400m
Reflective Sheet: MS05AX: ; 200m
Reflective Sheet: MS1AX: ; 300m
1 Prism: 3,500m for both
Non-Prism Mode: MS1AX: ; 2mm + 1ppm up to 200m
Reflective Sheet: MS05AX: ; 0.5mm + 1ppm
Reflective Sheet: MS1AX: ; 1mm + 1ppm
1 Prism: MS05AX: ; 0.8mm + 1ppm
1 Prism: MS1AX: ; 1mm + 1ppm
Minimum Reading: MS05AX: ; 0.01mm / 0.1mm
Minimum Reading: MS1AX: ; 0.1mm / 1mm
Operating Temperature: -10 to +50 ºC
Storage Temperature: -30 to +70 ºC"}
Angle Measurement
Accuracy*: MS05AXII: ; 0.5” (0.15mgon*)Accuracy*: MS1AXII: ; 1” (0.3mgon*)
Minimum Reading: MS05AX: ; 0.1 inch (0.02 mgon)
Minimum Reading: MS1AX: ; 0.5 inch( 0.1 mgon)
Distance Measurement
Non-Prism Mode: MS05AX: ; 100mNon-Prism Mode: MS1AX: ; 400m
Reflective Sheet: MS05AX: ; 200m
Reflective Sheet: MS1AX: ; 300m
1 Prism: 3,500m for both
Accuracy
Non-Prism Mode: MS05AX: ; 1mm + 1ppmNon-Prism Mode: MS1AX: ; 2mm + 1ppm up to 200m
Reflective Sheet: MS05AX: ; 0.5mm + 1ppm
Reflective Sheet: MS1AX: ; 1mm + 1ppm
1 Prism: MS05AX: ; 0.8mm + 1ppm
1 Prism: MS1AX: ; 1mm + 1ppm
Minimum Reading: MS05AX: ; 0.01mm / 0.1mm
Minimum Reading: MS1AX: ; 0.1mm / 1mm
Physical and Environmental
Ingress Protection: IP-64Operating Temperature: -10 to +50 ºC
Storage Temperature: -30 to +70 ºC"}